<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dcterms="http://purl.org/dc/terms/">
<rdf:Description rdf:about="http://catalogo.oftalmologos.org.ar/items/show/6678">
    <dcterms:title><![CDATA[Refracción Médica]]></dcterms:title>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Refracci%C3%B3n">Refracción</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=%C3%93ptica">Óptica</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Emetropizaci%C3%B3n">Emetropización</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Astigmatismo">Astigmatismo</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Prescripci%C3%B3n+de+anteojos">Prescripción de anteojos</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Lentes+de+contacto">Lentes de contacto</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Oftalmoscop%C3%ADa">Oftalmoscopía</a>]]></dcterms:subject>
    <dcterms:description><![CDATA[La refracción es tanto un arte como una ciencia. Este libro desglosa los métodos de refracción objetiva y subjetiva, brindando a residentes y profesionales las herramientas necesarias para realizar evaluaciones precisas y eficientes.<br />
<br />
Desde los fundamentos de la óptica geométrica hasta el manejo de casos complejos y astigmatismos irregulares, ofrece una guía paso a paso para perfeccionar la prescripción óptica y mejorar la satisfacción visual del paciente.<br />
<br />
Aborda de manera exhaustiva las ametropías, la retinoscopía, la refracción ciclopléjica y las tecnologías de vanguardia en aberrometría, uniendo la teoría óptica con la práctica médica cotidiana.<br />
<br />
Estructurado para una consulta rápida y efectiva, es la referencia indispensable para todo oftalmólogo.]]></dcterms:description>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Kotlik%2C+Carlos">Kotlik, Carlos</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Albertazzi%2C+Roberto">Albertazzi, Roberto</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Comastri%2C+Silvia">Comastri, Silvia</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Dom%C3%ADnguez%2C+Julieta">Domínguez, Julieta</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Fern%C3%A1ndez+Irigaray%2C+Leonardo+">Fernández Irigaray, Leonardo </a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Gal%C3%A1n%2C+Mar%C3%ADa+Marta">Galán, María Marta</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Gomez%2C+Guillermo">Gomez, Guillermo</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Iribarren%2C+Rafael">Iribarren, Rafael</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Marceillac%2C+Jorge">Marceillac, Jorge</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Pf%C3%B6rtne%2C+Tom%C3%A1s">Pförtne, Tomás</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Reca%2C+Virginia">Reca, Virginia</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Rocha+de+Lossada%2C+Carlos">Rocha de Lossada, Carlos</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Silva+Lara%2C+Ricardo">Silva Lara, Ricardo</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Szeps%2C+Abel">Szeps, Abel</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Martin%2C+Gabriel">Martin, Gabriel</a>]]></dcterms:creator>
    <dcterms:publisher><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=45&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Consejo+Argentino+de+Oftalmolog%C3%ADa">Consejo Argentino de Oftalmología</a>]]></dcterms:publisher>
    <dcterms:created><![CDATA[2026]]></dcterms:created>
    <dcterms:format><![CDATA[Libro]]></dcterms:format>
    <dcterms:extent><![CDATA[373 p., il. fots. col.]]></dcterms:extent>
    <dcterms:language><![CDATA[Español]]></dcterms:language>
    <dcterms:identifier><![CDATA[978-987-1572-45-8]]></dcterms:identifier>
</rdf:Description><rdf:Description rdf:about="http://catalogo.oftalmologos.org.ar/items/show/6672">
    <dcterms:title><![CDATA[La refracción es un acto médico: detección de melanoma conjuntival oculto]]></dcterms:title>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Refracci%C3%B3n">Refracción</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Melanoma+de+conjuntiva">Melanoma de conjuntiva</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Examen+oftalmol%C3%B3gico">Examen oftalmológico</a>]]></dcterms:subject>
    <dcterms:description><![CDATA[Es común creer que la toma de agudeza visual y corrección con lentes de miopía, astigmatismo, hipermetropía o presbicia es suficiente para evaluar la salud de nuestros ojos]]></dcterms:description>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Rudzinski%2C+Nicol%C3%A1s+Iv%C3%A1n+">Rudzinski, Nicolás Iván </a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Rudzinski%2C+Ivo+Valent%C3%ADn+">Rudzinski, Ivo Valentín </a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Rudzinski%2C+C%C3%A9sar+Diego+">Rudzinski, César Diego </a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Bonetti%2C+Bruno+">Bonetti, Bruno </a>]]></dcterms:creator>
    <dcterms:publisher><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=45&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Consejo+Argentino+de+Oftalmolog%C3%ADa">Consejo Argentino de Oftalmología</a>]]></dcterms:publisher>
    <dcterms:created><![CDATA[2025]]></dcterms:created>
    <dcterms:isPartOf><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=70&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Oftalmolog%C3%ADa+Cl%C3%ADnica+y+Experimental%2C+vol.+18%2C+nro.+3%2C+sep.+de+2025%2C+p.+400-402">Oftalmología Clínica y Experimental, vol. 18, nro. 3, sep. de 2025, p. 400-402</a>]]></dcterms:isPartOf>
    <dcterms:extent><![CDATA[2 p.]]></dcterms:extent>
    <dcterms:language><![CDATA[Español]]></dcterms:language>
    <dcterms:type><![CDATA[Artículo]]></dcterms:type>
    <dcterms:identifier><![CDATA[1851-2658]]></dcterms:identifier>
</rdf:Description><rdf:Description rdf:about="http://catalogo.oftalmologos.org.ar/items/show/6651">
    <dcterms:title><![CDATA[Seclusión pupilar hialoide: hialoidectomía anterior en la cámara retroiridiana. Una novedosa técnica para el glaucoma agudo de ángulo cerrado secundario a bloqueo pupilar postraumático por herniación del cuerpo vítreo con membrana hialoide intacta enclavada]]></dcterms:title>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Glaucoma+agudo">Glaucoma agudo</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Bloqueo+pupilar">Bloqueo pupilar</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Catarata">Catarata</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Luxaci%C3%B3n+anterior+de+la+lente">Luxación anterior de la lente</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Hialoides">Hialoides</a>]]></dcterms:subject>
    <dcterms:description><![CDATA[Se presenta un caso inusual de hernia vítrea pupilar con hialoides intacta, asociado a luxación anterior del lente intraocular, bolsa capsular intacta y zónula parcialmente íntegra, en un paciente de 85 años con glaucoma agudo postraumático inmediatamente posterior a  cirugía de catarata. Ante la ausencia de informes similares, se propuso una técnica quirúrgica innovadora: hialoidectomía anterior en la cámara retroiridiana. Este procedimiento mínimamente invasivo, realizado mediante iridectomía periférica, incluye vitrectomía anterior retroiridiana prelental, facilitando el reposicionamiento espontáneo de la prótesis intraocular. Los resultados visuales y anatómicos fueron favorables, demostrando la eficacia potencial de esta técnica para cirujanos de segmento anterior.]]></dcterms:description>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Alza%2C+Andr%C3%A9s+Germ%C3%A1n">Alza, Andrés Germán</a>]]></dcterms:creator>
    <dcterms:publisher><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=45&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Consejo+Argentino+de+Oftalmolog%C3%ADa">Consejo Argentino de Oftalmología</a>]]></dcterms:publisher>
    <dcterms:created><![CDATA[2025]]></dcterms:created>
    <dcterms:isPartOf><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=70&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Oftalmolog%C3%ADa+Cl%C3%ADnica+y+Experimental%2C+vol.+18%2C+nro.+2%2C+jul.+de+2025%2C+p.+243-260%0D%0A">Oftalmología Clínica y Experimental, vol. 18, nro. 2, jul. de 2025, p. 243-260<br />
</a>]]></dcterms:isPartOf>
    <dcterms:format><![CDATA[Artículo]]></dcterms:format>
    <dcterms:extent><![CDATA[17 p.]]></dcterms:extent>
    <dcterms:language><![CDATA[Español]]></dcterms:language>
    <dcterms:type><![CDATA[Texto]]></dcterms:type>
    <dcterms:identifier><![CDATA[1851-2658]]></dcterms:identifier>
</rdf:Description><rdf:Description rdf:about="http://catalogo.oftalmologos.org.ar/items/show/6649">
    <dcterms:title><![CDATA[Los ojos pueden permanecer sanos después de 40 años de una lente de cámara anterior]]></dcterms:title>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Lente+intraocular+de+c%C3%A1mara+anterior">Lente intraocular de cámara anterior</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Extracci%C3%B3n+intracapsular+de+cataratas">Extracción intracapsular de cataratas</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Microscop%C3%ADa+endotelial">Microscopía endotelial</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Refracci%C3%B3n">Refracción</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Calidad+visual">Calidad visual</a>]]></dcterms:subject>
    <dcterms:description><![CDATA[Objetivo: Presentar el caso de un paciente con una lente intraocular de cámara anterior (LIO-CA) durante 40 años, sin complicaciones, destacando que cuando la indicación del paciente es adecuada, son implantes seguros.<br />
<br />
Caso clínico: Presentamos el caso de una mujer de 85 años de edad que acudió al servicio de oftalmología para valoración de salud visual general y por presencia de hiposfagma en ojo derecho (OD). Como datos relevantes, encontramos que en el ojo derecho (OD) se había realizado una extracción de catarata extracapsular en el pasado, con colocación de una LIO de cámara posterior; en el ojo izquierdo (OI) se había realizado extracción de catarata intracapsular, con implante de una LIO-CA con más de 40 años de antigüedad. En la exploración física se encontró una agudeza visual de 20/100 OD y 20/80 OI. Agudeza visual mejor corregida de 20/50 RE y 20/40 LE. Paquimetría de 526 micras en OD y 538 micras en OI, presión intraocular de 15 mmHg en OD y 16 mmHg en OI. Refracción OD: -4,00 -3,75 177° y OI -6,50 -2,75 50°. La densidad de células endoteliales era en el OD de 1786 células/mm2 y 2552 células/mm2 en el OI. El pleomorfismo y el polimegatismo fueron normales en cada ojo.<br />
<br />
Conclusiones: Este caso representa que si el paciente es elegido correctamente, el implante de una LIO de cámara anterior puede dar buenos resultados anatómicos y funcionales sin complicaciones, incluso 40 años después de la cirugía.]]></dcterms:description>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Le+Roy+Marz%2C+Christian">Le Roy Marz, Christian</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Ib%C3%A1%C3%B1ez+Hern%C3%A1ndez%2C+Miguel+%C3%81ngel">Ibáñez Hernández, Miguel Ángel</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=P%C3%A9rez+Pacheco%2C+Arturo+Iv%C3%A1n">Pérez Pacheco, Arturo Iván</a>]]></dcterms:creator>
    <dcterms:publisher><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=45&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Consejo+Argentino+de+Oftalmolog%C3%ADa">Consejo Argentino de Oftalmología</a>]]></dcterms:publisher>
    <dcterms:created><![CDATA[2025]]></dcterms:created>
    <dcterms:isPartOf><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=70&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Oftalmolog%C3%ADa+Cl%C3%ADnica+y+Experimental%2C+vol.+18%2C+nro.+2%2C+jul.+de+2025%2C+p.+229-235">Oftalmología Clínica y Experimental, vol. 18, nro. 2, jul. de 2025, p. 229-235</a>]]></dcterms:isPartOf>
    <dcterms:format><![CDATA[Artículo]]></dcterms:format>
    <dcterms:extent><![CDATA[6 p.]]></dcterms:extent>
    <dcterms:language><![CDATA[Español]]></dcterms:language>
    <dcterms:type><![CDATA[Texto]]></dcterms:type>
    <dcterms:identifier><![CDATA[1851-2658]]></dcterms:identifier>
</rdf:Description><rdf:Description rdf:about="http://catalogo.oftalmologos.org.ar/items/show/6612">
    <dcterms:title><![CDATA[Comparación de la predictibilidad obtenida entre tres biómetros para el cálculo de la lente intraocular]]></dcterms:title>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Cataratas">Cataratas</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Cirug%C3%ADa+de+cataratas">Cirugía de cataratas</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Bi%C3%B3metros">Biómetros</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Lentes+intraoculares">Lentes intraoculares</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Refracci%C3%B3n">Refracción</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Lenstar">Lenstar</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Pentacam">Pentacam</a>]]></dcterms:subject>
    <dcterms:subject><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=49&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Argos">Argos</a>]]></dcterms:subject>
    <dcterms:description><![CDATA[Objetivo: Comparar el grado de predictibilidad refractiva obtenida entre tres biómetros oculares.<br />
Materiales y métodos: Estudio retrospectivo, unicéntrico, comparativo de una serie de casos de ojos medidos con tres biómetros diferentes (Lenstar LS900, Pentacam y Argos) entre octubre y diciembre de 2024. Se realizó el cálculo de la lente intraocular Alcon SA60AT mediante cuatro fórmulas: Haigis, SRK/T, Hoffer Q y Barret Universal II, tomando como referencia Haigis. Se evaluó el nivel de predicción al comparar los valores preoperatorios obtenidos con cada biómetro y la diferencia con equivalente esférico postoperatorio obtenido. Para evaluar la correlación entre las mediciones se realizó un test de regresión lineal de Pearson. Las diferencias entre las mediciones de cada biómetro se realizaron mediante el análisis de la varianza (ANOVA).<br />
Resultados: Se incluyeron 63 ojos. El valor medio de las lentes a implantar fue de 21,52 ± 1,69 D (18,5 a 25,0). Al comparar el valor preoperatorio calculado menos el equivalente esférico obtenido, para el Lenstar LS900 fue de -0,005 ± 0,58 (-2,2 a 1,6), para el Pentacam fue de -0,15 ± 0,62 (-2,6 a 1,2) y para el Argos fue de -0,04 ± 0,56 (-2,5 a 1,2). El Pentacam fue el único que mostró una diferencia estadísticamente significativa.<br />
Conclusión: En la muestra evaluada no se encontraron diferencias en el valor predictivo para el Lenstar LS900 y el Argos, pero con el Pentacam el equivalente esférico obtenido fue estadísticamente inferior al valor preoperatorio calculado.]]></dcterms:description>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Canegallo%2C+Lusina">Canegallo, Lusina</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Schunk%2C+Marcos">Schunk, Marcos</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Maldacena%2C+Paula">Maldacena, Paula</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Bordon%2C+Federico">Bordon, Federico</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Letroye%2C+Adri%C3%A1n">Letroye, Adrián</a>]]></dcterms:creator>
    <dcterms:creator><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=39&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Maldacena%2C+Javier">Maldacena, Javier</a>]]></dcterms:creator>
    <dcterms:publisher><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=45&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Consejo+Argentino+de+Oftalmolog%C3%ADa">Consejo Argentino de Oftalmología</a>]]></dcterms:publisher>
    <dcterms:created><![CDATA[2025]]></dcterms:created>
    <dcterms:isPartOf><![CDATA[<a href="/items/browse?advanced%5B0%5D%5Belement_id%5D=70&advanced%5B0%5D%5Btype%5D=is+exactly&advanced%5B0%5D%5Bterms%5D=Oftalmolog%C3%ADa+Cl%C3%ADnica+y+Experimental%2C+vol.+18%2C+nro.+1%2C+mar.+de+2025%2C+p.+43-51">Oftalmología Clínica y Experimental, vol. 18, nro. 1, mar. de 2025, p. 43-51</a>]]></dcterms:isPartOf>
    <dcterms:format><![CDATA[Artículo]]></dcterms:format>
    <dcterms:extent><![CDATA[8 p.]]></dcterms:extent>
    <dcterms:language><![CDATA[Español]]></dcterms:language>
    <dcterms:type><![CDATA[Texto]]></dcterms:type>
    <dcterms:identifier><![CDATA[1851-2658]]></dcterms:identifier>
</rdf:Description></rdf:RDF>
